RGT-MT18 - Blind Power Controller 18 Level +TCR with RS485 ModBus
Failed to load pickup availability
Online payment by card – After completing the order, you will be redirected to the payment portal. You will receive a payment confirmation by email.
Cash on delivery – You pay the amount according to the payment instructions directly to the driver of the transport company.
Bank transfer – You will receive a proforma invoice by email no later than the next business day. It contains the account number you should specify when making the payment.
On account – This payment method is available to partners who have concluded a framework agreement with our company.
If you want to use one of the last two payment methods, please contact our manager. He will give you instructions on how to receive an invoice with or without VAT.
The electrical devices we supply meet high quality standards, have a 24-month warranty, and comply with all EU requirements. In case of a complaint, no return shipping fee will be charged.
18 steps + TCR Power factor controller for symmetrical/asymmetrical networks with 5 inch touchscreen and RS-485 (TENSE)
Reactive power regulation relays are designed to reduce reactive power (inductive and capacitive) that is not used by the load and is drawn from the grid. When inductive power is drawn from the grid, the relay intervenes by removing a capacitor of an appropriate value. When capacitive power is taken from the electricity grid, it intervenes by taking a shunt inductor of the correct value. In this way, it attempts to reduce the inductive/active and capacitive/active speeds of the system. It is designed to provide a more reasonable compensation in unbalanced inductive and capacitive systems with the RGT-MT18 TCR step.
Generator input and generator compensation
Voltage, harmonic current/voltage, inductive and capacitive alarm output
Starting, discharging, and settling times can be adjusted
Remote communication via RS485 (RS485 ModBus RTU)
Single-phase, two-phase, and three-phase capacitors and shunt reactors can be connected
Harmonic voltage and current can be observed up to the 61st harmonic
Total energy (import/export) can be monitored
THD-V and THD-I values of each phase can be viewed
Create power analysis (20 samples 9999 min.) - for capacitor selection
Temperature alarm output
Demand registration (active and reactive and apparent power and current demand)
Minimum, maximum, and average current and voltage values of each phase can be monitored
Current date and time