Direct digital load relay with 3×3-digit LED display, 3-phase with timer, range 0.1-25 A, manufacturer TENSE (Turkey)

Digital thermal relays are designed to prevent and control damage to loads caused by high current.

- 0.1-25 A (adjustable overcurrent value)
- 50% fixed current asymmetry
- Adjustable fault delay time
- Operating mode: adjustable (automatic, semi-automatic, manual)
- Internal current transformers


Application and operating principle of the device

Connect the device according to the wiring diagram. Connect the device according to the wiring diagram. After switching on, the display shows the set values for 5 seconds.

- Use the controller "A>" to set the overcurrent value . The set value is displayed on the left display.
- Use the controller "t" to set the delay time . The set value is also displayed on the left display.

When the device is powered, the relay is energized, switches the output contact to terminal 3, and the OUT indicator lights up. If the current exceeds the set overcurrent value (A>), the device starts counting down the delay time and the ERR indicator lights up. After the time has elapsed, the relay switches off, the contact switches to terminal 1, and the OUT indicator goes out.

The TRM-12 series electronic current relay is designed to automatically switch off devices when the maximum allowed current is exceeded, with programmable cutoff range, cutoff time, and return time settings.
There are also 3 modes for returning to the "operational" status - MANUAL, SEMI-AUTOMATIC, AUTOMATIC.


Reset modes:

- Manual mode: After an overcurrent fault, the device must be reset by pressing the reset button. In this mode, the corresponding LED is lit.
- Semi-automatic mode: The device automatically resets the system three times when an overcurrent fault occurs and then waits for a manual reset when another fault occurs. In this mode, the corresponding LED blinks.
- Automatic mode: The device automatically resets the system every time an overcurrent fault occurs. In this mode, the corresponding LED blinks.

Note: Hold the selection button for 10 seconds to change the mode. When the mode is changed, the corresponding LED will light up.


Asymmetry 50% (fixed)

If the difference between the largest and smallest phase current is greater than 50%, the device switches to asymmetry fault mode within 2 seconds.
(During the operation of the motor, this prevents damage to the system in the event of a single phase failure).

During an asymmetry fault:
- The display group of the two phases that caused the fault flashes and the ERR indicator lights up.
- If the current is less than 2 A, the device does not check for asymmetry.
- To exit the asymmetry fault mode, the device must be manually reset.



Technical parameters

- Operating voltage: 150-260 VAC
- Operating frequency: 50/60 Hz
- Power consumption: < 6 VA
- Operating temperature: -20 °C to +55 °C
- Display: 3×3 digits, 5 LEDs
- Overcurrent setting (A>): 0.1-25 A
- Delay time: 0.1-20 s
- Connection type: terminal connection
- Contacts: 5 A / 250 V AC (active load)
- Wire diameter: 2.5 mm²
- Weight: max. 250 g
- Mounting: on DIN rail
- Height during use: < 2000 m


Note: The TRM-50, TRM-100, TRM-200, and TRM-300 can only be used with the supplied current transformers.

The TRM-400 can be used with the 400/5 current transformer supplied with the TRM-400.

Base

Manufacturer

Voltage

Country of manufacture

Turkey

Type of installation

DIN rail mounting

Number of expansion contacts

1 piece

Number of switching contacts

1 piece

Cross-section of connected wires

2.5 mm²

Housing material

Plastic

View

Yes

Mass

250 g

On/Off LED

Yes

"LED "Overload

Yes

Minimum storage temperature

-20 degrees

Maximum storage temperature

55 degrees.

Protection level IP

30

Service life

10 years

Technical specifications

Number of phases

3

Rated AC operating voltage

220V

Rated current

5A

Current frequency

50 Hz

Rated current

3W

Minimum operating temperature

-20 degrees

Maximum operating temperature

55 degrees.

Overall dimensions

Length

85 mm

Height

75 mm

Width

44 mm

User characteristics

Delay time

0,1 s - 20 (s)

Installation

DIN+ screws

Range

0,1-20A

Manual